3 sensors in a single meter
* pH electrode with extractable junction
* Amperometric EC/TDS sensor
* Exposed temperature probe for faster EC/TDS readings
Waterproof
- Designed to float if accidently dropped in sample
Wide pH Range
- pH range is from 0.00 to 14.00 pH
Selectable EC to TDS conversion factor
- Choice of either a 0.45 or 1.0 conversion factor
Automatic Temperature Compensation
- All readings are compensated for variations in temperature
- Temperature displayed in oC or oF along with pH, EC or TDS reading
Stability indicator
- Meter displays a clock tag that will disappear when the reading has achieved stability
HOLD button
- Freezes reading on the display to allow recording of measurement
BEPS (Battery Error Prevention System
- Meter will automatically shut off if there is not enough power to get an accurate measurement
Battery % level at startup
Low Battery Indicator
- When the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.
Auto-off
- Auto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life
Specification Name | Detail |
---|---|
SKU | HI98130 |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy (@25°C/77°F) | ±0.05 pH |
pH Calibration | automatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18) |
pH Temperature Compensation | automatic |
EC Range | 0.00 to 20.00 mS/cm |
EC Resolution | 0.01 mS/cm |
EC Accuracy | ±2% F.S. |
TDS Range | 0.00 to 10.00 g/L (ppt) |
TDS Resolution | 0.01 g/L (ppt) |
TDS Accuracy | ±2% F.S. |
TDS Calibration | automatic, one point at 12.88 mS/cm or 6.44 g/L (ppt) |
Temperature Correction Coefficient | automatic with у adjustable from 0.0 to 2.4% / °C |
EC to TDS Conversion Factor | 0.45 to 1.00 |
Temperature Range | -5.0 to 60.0°C / 23.0 to 140.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Temperature Accuracy | ±0.5°C /±1°F |
pH Electrode | HI73127 (replaceable; included) |
Automatic Shut-Off | auto-off after 8 minutes of non-use |
Battery Type / Life | 1.5V (4) / approx. 100 hours of continuous use |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’) |
Weight | 100 g (3.5 oz.) |
Ordering Information | Each HI98130 is delivered in a cardboard box (see below) and is supplied with: HI70004 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI70007 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI70300N Storage solution for pH & ORP electrodes, 20 mL sachet (1 pc.), HI70030 12880 μS/cm conductivity standard, 20 mL sachet (1 pc.), HI70038 6.44 ppt TDS standard, 20 mL sachet (1 pc.), HI700601 pH & ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, 1.5V batteries (4 pcs.), Instrument quality certificate, & Instruction manual. |
Warranty | 1 year (Hanna Instruments) |